Engine fault codes D-245.7E3, D-245.9E3, D-245.30E3, D-245.35E3
Code table
Blink code (P-code) Type of malfunction Description of the malfunction Method and method of troubleshooting
Faults indicated by turning on the diagnostic lamp
1-1-1
- (P060V) A/D converter reference voltage is above the specified limit - Error detected by A/D converter monitoring function
- (P060V) The reference voltage of the analog-to-digital converter is below the specified limit
- (P060V) The test pulse voltage is outside the permissible limits
- (P060B) Error processing the queue with the analog-to-digital converter
2-2-1
- P0123 Voltage above the specified maximum limit - Malfunction of gas pedal position sensor 1
- P0122 Voltage below the specified minimum limit - Malfunction of gas pedal position sensor 1
- P2135 Plausibility with gas pedal position sensor 2 is broken - Malfunction of gas pedal position sensor 1
- P0223 Voltage above the specified maximum limit - Malfunction of gas pedal position sensor 2 - Check the condition and connection of the gas pedal position sensors.
- P0222 Voltage below the specified minimum limit - Malfunction of gas pedal position sensor 2 - Check the condition and connection of the gas pedal position sensors.
- P2135 Plausibility with gas pedal position sensor 1 is broken - Malfunction of gas pedal position sensor 2 - Check the condition and connection of the gas pedal position sensors.
2-3-2
- P2229 Voltage above the specified maximum limit - Malfunction in the atmospheric pressure sensor circuit (built-in sensor of the control unit) - Check the condition and connection of the sensor.
- P2228 Voltage below the specified minimum limit - Malfunction in the atmospheric pressure sensor circuit (built-in sensor of the control unit) - Check the condition and connection of the sensor
- P0000 Implausible signal value via CAN - Malfunction in the atmospheric pressure sensor circuit (built-in sensor of the control unit) - Check the condition and connection of the sensor
- P2227 Plausibility with the boost pressure sensor is broken - Malfunction in the atmospheric pressure sensor circuit (built-in sensor of the control unit) - Check the condition and connection of the sensor
2-3-1
- P0238 Voltage above the specified maximum limit - Malfunction in the boost pressure sensor circuit. Check the condition and connection of the boost pressure sensor.
- P0237 Voltage below the specified minimum limit - Malfunction in the boost pressure sensor circuit. Check the condition and connection of the boost pressure sensor.
- P0235 Implausible signal value via CAN - Malfunction in the boost pressure sensor circuit. Check the condition and connection of the boost pressure sensor.
- P0236 Implausible signal - Malfunction in the boost pressure sensor circuit. Check the condition and connection of the boost pressure sensor.
2-2-3
- P0571 Brake pedal sensor signal defective - There is a malfunction in the brake pedal sensor circuit. Check the condition and connection of the brake pedal position sensor.
- P0504 Implausible brake pedal sensor signal - There is a malfunction in the brake pedal sensor circuit. Check the condition and connection of the brake pedal position sensor.
3-2-5
- P0050 Short circuit to battery - Malfunction in the power stage circuit of the engine brake decompression throttle. Check the condition and connection of the engine brake decompression throttle.
- P004F Short circuit to ground - Malfunction in the power stage circuit of the engine brake decompression throttle. Check the condition and connection of the engine brake decompression throttle.
- P0661 No load resistance - Malfunction in the power stage circuit of the engine brake decompression throttle. Check the condition and connection of the engine brake decompression throttle.
- P0662 Exceeding the heating temperature - Malfunction in the power stage circuit of the engine brake decompression throttle. Check the condition and connection of the engine brake decompression throttle.
2-4-1
- P0118 Voltage above the specified maximum limit - Malfunction in the coolant temperature sensor circuit. Check the condition and connection of the coolant temperature sensor.
- P0117 Voltage below the specified minimum limit - Malfunction in the coolant temperature sensor circuit. Check the condition and connection of the coolant temperature sensor.
- P0115 Defective CAN signal - Malfunction in the coolant temperature sensor circuit. Check the condition and connection of the coolant temperature sensor liquid.
- P0116 Inconsistency between the oil temperature sensor and coolant temperature readings - Malfunction in the coolant temperature sensor circuit. Check the condition and connection of the coolant temperature sensor.
2-2-2
- P0704 Defective clutch status signal via CAN - Error recorded by the clutch status signal diagnostic function. Check the condition and connection of the clutch pedal position sensor. Check the connection of the CAN line to other CAN s
- P0704 Invalid clutch sensor signal - Error recorded by the clutch status signal diagnostic function. Check the condition and connection of the clutch pedal position sensor. Check the connection of the CAN line to other CAN s
1-1-3
- P0340 No camshaft speed sensor signal - Malfunction in the camshaft speed sensor circuit. Check the condition and connection of the camshaft speed sensor.
- P0341 Incorrect camshaft speed sensor signal - Malfunction in the camshaft speed sensor circuit. Check the condition and connection of the camshaft speed sensor.
1-1-2
- P0335 There is no signal from the crankshaft speed sensor. Malfunction in the crankshaft speed sensor circuit. Check the condition and connection of the crankshaft speed sensor.
- P0336 Incorrect crankshaft speed sensor signal - Malfunction in the crankshaft speed sensor circuit. Check the condition and connection of the crankshaft speed sensor.
1-1-4
P0016 Mismatch between the signals of the crankshaft and camshaft speed sensors - Mismatch between the signals of the crankshaft and camshaft speed sensors. Check the condition and connection of the camshaft and crankshaft speed sensors.
3-1-1
- P0478 Short circuit to battery. Exceeding the heating temperature - Short circuit to battery in the power cascade circuit for controlling the exhaust flap. Check the condition and connection of the exhaust flap.
- P0477 Short circuit to ground - Short circuit to ground in the exhaust flap control power stage circuit. Check the condition and connection of the exhaust flap.
- P0476 No load resistance
- P0476 Excessive heating temperature - Open circuit or unacceptable temperature in the exhaust flap control power stage circuit. Check the condition and connection of the exhaust flap.
2-1-3
- P1015 Voltage above the specified maximum limit - Malfunction in the fine fuel filter clogging sensor circuit. Check the condition and connection of the fine fuel filter clogging sensor. Contact the service center
- P1016 Voltage below the specified minimum limit - Malfunction in the fine fuel filter clogging sensor circuit. Check the condition and connection of the fine fuel filter clogging sensor. Contact the service center
- P1017 Implausible signal from the fine fuel filter clogged sensor - Malfunction in the fine fuel filter clogged sensor circuit. Check the condition and connection of the fine fuel filter clogging sensor. Contact the service center
2-1-2
P1018 Fine fuel filter clogged - Replace the fine fuel filter.
4-3-4
- U0158 DashDspl CAN message timeout - DashDspl CAN message error. Check the connection of the CAN line to other CAN devices. Contact the service center
- 4-4-1 P0000 Timeout for EBC1 CAN message - EBC1 CAN message error - Check the connection of the CAN line to other CAN devices. Contact the service center
- 4-4-2 U1100 Timeout for ERC1DR CAN message - ERC1DR CAN message error - Check the connection of the CAN line to other CAN devices. Contact the service center
- 4-4-3 U0103 Timeout for ETC1 CAN message - ETC1 CAN message error - Check the connection of the CAN line to other CAN devices. Contact the service center
- 4-4-5 U0104 The CAN error clearing function is inactive and the RxCCVS CAN message timeout has expired - RxCCVS CAN message error - Check the connection of the CAN line to other CAN devices. Contact the service center
- 4-4-6 U0157 Timeout for TCO1 CAN message - TCO1 CAN message error - Check the connection of the CAN line to other CAN devices. Contact the service center.
4-2-1
- U1104 Timeout expired for TSC1-AE CAN - messages if mode engine torque/speed correction active - Error TSC1-AE CAN message - Check the connection of the CAN line to other CAN devices.
- U1105 Timeout for TSC1-AE CAN message when torque/engine speed correction mode is not active
- U1106 Timeout for TSC1-AR CAN message when torque/engine speed correction mode is active - TSC1-AR CAN message error - Check the connection of the CAN line to other CAN devices.
4-2-2
- U1107 Timeout for TSC1-AR CAN message when torque/engine speed correction mode is not active
- U1108 Timeout for TSC1-DE CAN message when torque/engine speed correction mode is active - TSC1-DE CAN message error - Check the connection of the CAN line to other CAN devices.
- U1109 Timeout for TSC1-DE CAN message when torque/engine speed correction mode is not active
4-2-2
U110A Timeout expired for TSC1-DR CAN message, if torque/engine speed correction mode is active - TSC1-DR CAN message error - Check the connection of the CAN line to other CAN devices. Contact the service center.
4-2-3
- U110В Timeout for TSC1-DR CAN message if torque/engine speed correction mode is not active
- U110С Timeout expired for TSC1-PE CAN message, if torque/engine speed correction mode is active - TSC1-PE CAN message error - Check the connection of the CAN line to other CAN devices. Contact the service center
4-2-4
- U110D Timeout for TSC1-PE CAN message if torque/engine speed correction mode is not active
- U110E Timeout for TSC1-TE CAN message when torque/engine speed correction mode is active - TSC1-TE CAN message error - Check the connection of the CAN line to other CAN devices.
- U110F Timeout for TSC1-TE CAN message if torque/engine speed correction mode is not active
4-2-4
- U113A Timeout for TSC1-TR CAN message when torque/engine speed correction mode is active - TSC1-TR CAN message error - Check the connection of the CAN line to other CAN devices.
- U113B Timeout for TSC1-TR CAN message if torque/engine speed correction mode is not active
4-2-5
- U1110 Timeout for TSC1-VE CAN message when torque/engine speed correction mode is active - TSC1-VE CAN message error - Check the connection of the CAN line to other CAN devices.
- U1111 Timeout for TSC1-VE CAN message when torque/engine speed correction mode is not active
4-2-5
- U1112 Timeout for TSC1-VR CAN message when torque/engine speed correction mode is active - TSC1-VR CAN message error - Check the connection of the CAN line to other CAN devices.
- U1113 Timeout for TSC1-VR CAN message when torque/engine speed correction mode is not active
4-3-5
U1115 Timeout for WSI CAN message - WSI CAN message error - Check the connection of the CAN line to other CAN devices. Contact the service center
4-3-1
U0001 Timeout for messages sent to CAN - Error in CAN messages sent - Check the connection of the CAN line to other CAN devices. Contact the service center.
2-6-3
P060A Lost communication with the CJ940 electronic unit module - Lost communication with the power stages of the electronic unit controlled by SPI - Contact a service center.
2-6-1
P0607 A restart of the electronic unit has occurred - Restart of the electronic unit recorded as protective - Contact the service center
2-6-1
P0607 The electronic unit has restarted - Restart of the electronic unit is visible in the error memory - Contact the service center.
2-6-3
P1607 Internal supply voltage above the maximum limit - Error in the maximum supply voltage limit of the CJ940 module - Contact the service center
2-6-3
P1608 Internal supply voltage below minimum limit - CJ940 module supply voltage minimum limit error
2-3-3
- P0098 Voltage above the maximum limit - Malfunction in the air temperature sensor circuit
- P0097 Voltage below minimum limit
- P0099 Defective CAN signal
1-5-1
- P1203 Short circuit - Malfunction in the power cascade circuit for injector control Bank1, specific error, engine stop
- P1204 Low side short circuit to ground
- P1205 Depending on the setting
- P1206 Unclassifiable error
1-5-1
- P1207 Depending on the setting - Malfunction in the power stage circuit of the Bank1 injector control, specific warning, engine stop
- P1208 Depending on the setting
- P1209 No load resistance
- P120A Depending on the setting
1-5-2
- P120B Short circuit - Malfunction in the Bank2 injector control power stage circuit, specific error, engine stop
- P120C Short circuit Low side to ground
- Р120D Depending on the setting
- P120E Unclassifiable error
1-5-2
- Р120F Depending on the setting - Malfunction in the circuit of the power stage for controlling Bank2 injectors, specific warning, engine stop - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P1210 Depending on the setting
- P1211 No load resistance
- P1212 Depending on the setting
1-5-3
- P062B Chip CY33X internal reset / loss of counter / low voltage - Malfunction of the chip of the power stage of the injector control ChipA, specific error, engine stop - Contact a service center.
- P062B The CY33X chip is not allowed to work / CY33X initialization error
- Р062B Chip CY33X in test mode
- P062B Lost communication with the CY33X chip / check amount error / reverse check error
1-5-3
- P062B Chip CY33X internal equality error - Malfunction of the chip of the power stage of the injector control ChipB, specific error, engine stop - Contact a service center.
- Р062B Chip CY33X internal program algorithm error
- Р062B Chip CY33X check of inv. YSEL during ON failed
- Р062B Chip CY33X has exceeded the waiting time for at least one cylinder
1-4-1
- P0262 Low side short circuit to battery - Malfunction in the power stage control circuit of cylinder 1, specific error, engine stop - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P0263 Depending on the setting
- P0261 Short circuit Low side and High side
- P0263 Unclassifiable error
1-4-1
- P1213 Depending on the setting - Malfunction in the power stage control circuit of cylinder 1, specific warning - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P1214 Depending on the setting
- P0201 No load resistance
- P1215 Depending on the setting
1-4-2
- P0265 Low side short circuit to battery - Malfunction in the power stage control circuit of cylinder 2, specific error, engine stop - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P0266 Depending on the setting
- P0264 Short circuit Low side and High side
- P0266 Unclassifiable error
1-4-2
- P1216 Depending on the setting Malfunction in the circuit of the power stage control of cylinder 2, specific warning - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P1217 Depending on the setting
- P0202 No load resistance
- P1218 Depending on the setting
1-4-3
- P0268 Low side short circuit to battery - Malfunction in the power stage control circuit of cylinder 3, specific error, engine stop - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P0269 Depending on the setting
- P0267 Short circuit Low side and High side
- P0269 Unclassifiable error
1-4-3
- P1219 Depending on the setting Malfunction in the circuit of the power stage control of cylinder 3, specific warning - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P121A Depending on the setting
- P0203 No load resistance
- P1218 Depending on the setting
1-4-4
- P0271 Low side short circuit to battery - Malfunction in the power stage control circuit of cylinder 4, specific error, engine stop - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P0272 Depending on the setting
- P0270 Short circuit Low side and High side
- P0272 Unclassifiable error
1-4-4
- P121C Depending on the setting - Malfunction in the circuit of the power stage control of cylinder 4, specific warning - Check the condition of the plugs and connecting cable of engine cylinder injectors.
- Р121D Depending on the setting
- P0204 No load resistance
- Р121E Depending on setting
1-5-4
- P1225 The number of working cylinders is less than the specified minimum limit - The number of working cylinders is less than the specified minimum limit, engine stops - Check the condition of the plugs and cable connecting the engine cylinder injectors.
- P0000 Not used
- P0000 Not used
- P0000 Not used
1-3-2
- P0687 Short circuit to battery - Malfunction in the main relay 2 circuit (control unit) - Check the condition and connection of the main relay.
- P0686 Short circuit to ground
1-3-2
P160E Short circuit to battery - Malfunction in the main relay 1 circuit (control unit) - Check the condition and connection of the main relay.
1-3-2
P160F Short circuit to ground - Malfunction in the main relay 1 circuit (control unit) - Check the condition and connection of the main relay.
2-6-4
P060C The controller or Watchdog surveillance system is not operating properly, or the system must stop operating - Monitoring function for communication between the Watchdog of CY310 and the controller. Used to reverse system operation using the engine coordinator function - Contact a service center.
4-1-1
U0029 Lack of CAN bus A Lack of CAN bus A - Check the connection of the CAN line to other CAN devices.
4-1-2
U0038 Lack of CAN B bus Lack of CAN B bus - Check the connection of the CAN line to other CAN devices.
4-1-3
U0047 No CAN C bus No CAN C bus - Check the connection of the CAN line to other CAN devices.
2-4-3
- P0523 Voltage above the specified maximum limit - Malfunction in the oil pressure sensor circuit - Check the condition and connection of the oil pressure sensor
- P0522 Voltage below the specified minimum limit
- P0520 Defective signal from the sensor or via CAN
- P0521 Implausible signal, oil pressure too high
2-4-3
P0524 Implausible signal, oil pressure too low - Oil pressure sensor signal error, oil pressure too low - Check the condition and connection of the oil pressure sensor.
2-4-4
- P0198 Voltage above the specified maximum limit - Malfunction in the oil temperature sensor circuit - Check the condition and connection of the oil temperature sensor.
- P0197 Voltage below the specified minimum limit
- P0195 Defective CAN signal
- P100D Implausibility between the oil temperature and coolant temperature sensor readings
2-4-4
P0196 Implausible signal, oil temperature too high - Oil temperature sensor signal error, oil temperature too high - Check the condition and connection of the oil temperature sensor.
2-6-2
P1613 The excitation time of the injectors exceeds the limit specified in the monitoring function - Error recorded by the monitoring function of the electronic unit - Contact the service center
2-6-2
P1614 Implausibility between the engine speed calculated by the monitoring function and the main program - Error recorded by the electronic unit monitoring function using an independent calculation of engine speed - Contact a service center.
3-2-6
- P0629 Short circuit to battery - Malfunction in the power stage circuit for controlling the electric fuel pre-priming pump - Check the condition and connection of the electric fuel pre-priming pump.
- P0628 Short circuit to ground
- P0627 No load resistance
- P062A Heating temperature exceeded
1-1-6
P1616 The path for disabling the cylinders using the Watchdog module is faulty - A malfunction detected during unit initialization by the function of checking additional methods for disabling the power stages of cylinder control - Contact a service center.
P1617 The path for turning off the cylinders by the function of monitoring the maximum voltage limit of the power stage is faulty
P1618 The path for turning off the cylinders by the function of monitoring the minimum voltage limit of the power stage is faulty
1-3-1
- P0643 Voltage above the specified maximum limit Fault in the supply voltage of sensors 1
- P0642 Voltage below the specified minimum limit
1-3-1
- P0653 Voltage above the specified maximum limit. Malfunction of the supply voltage of sensors 2 - Contact a service center.
- P0652 Voltage below the specified minimum limit
1-3-1
- P0699 Voltage is higher than the specified maximum limit Malfunction of the supply voltage of sensors 3
- P0698 Voltage below the specified minimum limit
1-2-3
P2533 No signal from terminal 15 Malfunction in the terminal 15 circuit - Check the condition and connection of terminal 15.
1-2-2
P2530 Terminal 50 is always shorted - Malfunction in the terminal 50 circuit - Check the condition and connection of terminal 50.
1-1-5
P0607 Deviation between the time of the electronic time processor and the timer of the central processor - Error in the operation of the electronic time processor
3-2-4
- P0501 The vehicle speed according to the speed signal is higher than the maximum set vehicle speed - Vehicle speed measurement fault, path 1 - Check the condition and connection of the vehicle speed measurement sensor. Check connection to tachograph. Check the connection of the CAN line to other CAN devices.
- P0500 Defective vehicle speed signal associated with a malfunction of the electronic unit hardware
- P0501 Implausible vehicle speed, given the amount of fuel injected and engine speed
3-2-4
- P2158 Signal voltage above the specified maximum limit - Vehicle speed measurement fault, path 2 - Check the condition and connection of the vehicle speed measurement sensor. Check connection to tachograph. Check the connection of the CAN line to other CAN devices.
- P2160 Signal voltage below the specified minimum limit
- P2157 Defective vehicle speed signal received via CAN
- P2159 Implausible vehicle speed signal voltage
3-2-4
- P1511 The speed signal pulse width is above the specified maximum limit - Vehicle speed measurement fault, path 3 - Check the connection to the tachograph. Contact the service center
- P1512 The speed signal pulse width is below the specified minimum limit
- P1513 Defective frequency of the vehicle speed signal associated with a malfunction of the electronic unit hardware
4-1-4
P0607 SPI communication failure between the central processor and the monitoring unit - SPI communication failure between the central processor and the monitoring unit - Contact the service center.
1-3-5
- P0251 No load resistance - Malfunction in the circuit of the power stage of the pulse-width control of the high-pressure fuel pump dispenser - Check the condition and connection of the high-pressure fuel pump dispenser. Contact the service center
- P0252 Heating temperature exceeded
1-3-5
- P0254 Short circuit to battery - Malfunction in the power stage circuit of the pulse-width control of the high-pressure fuel pump metering device - Check the condition and connection of the high-pressure fuel pump metering device.
- P0253 Short circuit to ground - Malfunction in the circuit of the power stage of the pulse-width control of the high-pressure fuel pump metering device - Check the condition and connection of the high-pressure fuel pump metering device.
- P025D The signal voltage is above the specified maximum limit - Malfunction of the channel of the analog-to-digital converter for controlling the fuel pump metering pump - Check the condition and connection of the high pressure fuel pump metering device.
- P025C Signal voltage below the specified minimum limit
1-3-4
- P100E Safety valve detected as open - Malfunction of the fuel pressure safety valve in the rail - Contact a service center.
- Р100F Rail pressure surge requested
- P1010 The safety valve did not open after a pressure surge in the rail
1-3-6
- P1011 The number of openings of the safety valve exceeds the number allowed by its technical characteristics - Malfunction of the fuel pressure safety valve in the rail, determined on the basis of data on its operation - Contact a service center.
- P1012 The open time of the safety valve exceeds the time allowed by its technical characteristics
- P1013 The number of openings and the open time of the safety valve exceed the number and time allowed by its technical characteristics
1-3-3
- P0193 Voltage above the specified maximum limit - Malfunction in the rail fuel pressure sensor circuit - Check the condition and connection of the rail fuel pressure sensor. Contact the service center
- P0192 Voltage below the specified minimum limit
1-3-3
- P0191 The signal from the fuel pressure sensor in the rail is higher than the maximum permissible when monitoring the signal offset - Malfunction of the fuel pressure sensor in the rail, monitoring the signal offset - Check the condition and connection of the fuel pressure sensor in the rail. will convert Go to the service center
- P0191 The signal from the fuel pressure sensor in the rail is below the minimum permissible when monitoring the signal offset
2-5-1
P1011 The maximum positive deviation of the fuel pressure in the rail has been exceeded - Violation of the high pressure fuel pump metering control mode - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
2-5-2
P1012 The maximum positive deviation of the fuel pressure in the rail has been exceeded when the specified pump flow is exceeded - Violation of the high pressure fuel pump metering control mode - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
2-5-4
P1013 The maximum negative deviation of the fuel pressure in the rail has been exceeded with a minimum supply of the fuel pump metering unit - Violation of the control mode of the high pressure fuel pump metering unit - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
2-5-3
P0087 Fuel pressure in the rail is below the minimum set limit - Violation of the high pressure fuel pump metering control mode - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
2-5-3
P0088 Fuel pressure in the rail is above the maximum set limit - Violation of the high pressure fuel pump metering control mode - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
2-5-7
P101A The degree of pressure drop in the rail is higher than expected - Violation of the high pressure fuel pump metering control mode - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
2-5-5
P1014 Implausible fuel pump metering set point in pump overflow mode - Violation of the high pressure fuel pump metering control - Check the condition and connections of the high and low pressure hydraulic circuit components.
2-5-6
P1018 Filtered fuel pump metering current is below the minimum permissible current - Violation of the high pressure fuel pump metering control mode - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
2-5-4
P1019 The maximum positive deviation of the fuel pressure in the rail has been exceeded at a given pump flow - Violation of the high pressure fuel pump metering control mode - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
1-3-1
- P1640 Voltage above the specified maximum limit - Malfunction of the 12V sensor supply voltage - Contact the service center
- P1641 Voltage below the specified minimum limit
1-2-1
- P0617 Short circuit to battery - Malfunction in the power stage circuit for controlling the starter relay. High voltage level - Check the condition and connection of the starter relay.
- P0616 Short circuit to ground
1-2-1
- P1638 Short circuit to battery - Malfunction in the power stage circuit of the starter relay control - Low voltage level - Check the condition and connection of the starter relay.
- P1639 Short circuit to ground - No load resistance
2-4-2
P163A Coolant temperature is higher than the maximum permissible - Coolant overheating
2-3-2
- P2229 Voltage above the maximum physical limit - Malfunction in the atmospheric pressure sensor circuit, check the physical limit - Check the condition and connection of the atmospheric pressure sensor.
- P2228 Voltage below the minimum physical limit
2-3-1
- P0238 Voltage above the maximum physical limit - Malfunction in the boost pressure sensor circuit, check the physical limit - Check the condition and connection of the boost pressure sensor
- P0237 Voltage below the minimum physical limit
2-4-1
- P0118 Voltage above the maximum physical limit - Malfunction in the coolant temperature sensor circuit, check the physical limit - Check the condition and connection of the coolant temperature sensor.
- P0117 Voltage below the minimum physical limit
3-2-8
P2106 Engine performance limitation mode is active - Engine performance limitation mode is active - Contact a service center.
2-2-9
P0741 Invalid rotation speed of the turbine wheel of the torque converter - Error in determining the speed of rotation of the turbine wheel of the torque converter - You can continue driving. Contact the service center.
2-3-3
- P0098 Voltage above maximum physical boundary - Malfunction in the incoming air temperature sensor circuit, checking the physical boundary - Check the condition and connection of the incoming air temperature sensor.
- P0097 Voltage below the minimum physical limit
2-5-8
P101B The fuel pump flow when the engine is idling exceeds the specified maximum value - Violation of the high pressure fuel pump metering control mode - Check the condition and connections of the components of the high and low pressure hydraulic circuits.
2-2-3
P0504 Brake sensor faulty - Malfunction in the brake pedal position sensor circuit, when using one sensor - Check the condition and connection of the brake pedal position sensor.
2-2-3
P0504 The cruise control function is disabled until the operation of the brake pedal position sensor is checked - Error signal indicating that the cruise control function is disabled before the operation of the brake pedal position sensor is checked - Press the brake pedal. If the error persists, check the condition and connection of the brake pedal position sensor.
2-2-3
P0504 The cruise control function is disabled until the operation of the brake pedal position sensor is checked. Diagnostic lamp is on - Error signal for turning on the diagnostic lamp, indicating that the cruise control function is disabled until the function of the brake pedal position sensor is checked - Press the brake pedal. If the error persists, check the condition and connection of the brake pedal position sensor. Faults not indicated by the diagnostic lamp turning on
2-3-4
- P0113 Voltage above the specified maximum limit - Malfunction in the incoming air temperature sensor circuit in the air mass meter - Check the condition and connection of the sensor - Contact a service center
- P0112 Voltage below the specified minimum limit
2-3-4
- P0101 The signal voltage of the mass air flow meter is above the specified limit - An error recorded by the function of checking the plausibility of the initial deviation from the standard voltage of the signal of the mass air flow meter - Check the condition and connection of the mass air flow meter.
- P0101 Signal voltage of the air mass meter is below the specified limit
2-3-4
- P0103 The coefficient of the mass air flow meter is above the specified limit - Error recorded by the function of checking the plausibility of the deviation of the signal sensitivity of the mass air flow meter - Check the condition and connection of the mass air flow meter.
- P0102 Air mass meter coefficient is below the specified limit
- P0103 Recorded mass air flow rate above the specified limit - Error recorded by the function of checking the signal limits of the mass air flow meter - Check the condition and connection of the mass air flow meter.
- P0102 Recorded mass air flow below the specified limit
- P0649 Short circuit to battery - Malfunction in the variable speed limit lamp circuit - Check the condition and connection of the lamp. Contact the service center
- P0649 Short circuit to ground
- P0649 No load resistance
- P0649 Heating temperature exceeded
2-2-5
P2299 The gas pedal signal is not plausible - Error recorded by the function of checking the plausibility of the gas pedal and brake pedal - Check the condition and connection of the gas and brake pedal position sensors.
3-2-2
- P0540 Defective multi-signal - Air preheater is always on - Check the condition and connection of the air preheater.
- P1020 Change in battery voltage when air preheating is turned on is greater than the specified maximum threshold - Error recorded by the air preheating check function - Check the condition and connection of the air preheating device.
- P1021 The change in battery voltage when air preheating is turned on is less than the specified minimum threshold
- P1022 Change in battery voltage when air preheating is turned off is greater than the specified maximum threshold - Error recorded by the air preheating shutdown check function - Check the condition and connection of the air preheating device. Contact the service center
- P1023 Change in battery voltage when air preheating is turned off is less than the specified minimum threshold
- P0542 Short circuit to battery - Malfunction in the air preheater power stage circuit - Check the condition and connection of the air preheater
- P0541 Short circuit to ground
- P0563 Voltage higher than specified maximum limit - Inadmissible battery voltage - Check the condition and connection of the battery. Contact the service center
- P0562 Voltage below the specified minimum limit
2-4-5
P0116 Minimum coolant temperature not reached within a specified period of time - Error recorded by the absolute plausibility check function of the coolant temperature sensor - Check the condition and connection of the coolant temperature sensor. Contact the service center.
2-4-5
P0116 The minimum increase in coolant temperature has not been achieved within the specified period of time - Error recorded by the coolant temperature sensor dynamic plausibility check function - Check the condition and connection of the coolant temperature sensor. Contact the service center.
5-1-1
P0301 The number of detected misfires is above the specified limit - Error recorded by the misfire control function in 1 cylinder - Check the condition of the plugs and cable connecting the engine cylinder injectors.
5-1-2
P0302 The number of detected misfires is above the specified limit - Error recorded by the misfire monitoring function in cylinder 2 - Check the condition of the plugs and cable connecting the engine cylinder injectors. Contact the service center.
5-1-3
P0303 The number of detected misfires is above the specified limit - Error recorded by the misfire control function in cylinder 3 - Check the condition of the plugs and cable connecting the engine cylinder injectors.
5-3-1
P0304 The number of detected misfires is above the specified limit - Error recorded by the misfire monitoring function in cylinder 4 - Check the condition of the plugs and cable connecting the engine cylinder injectors.
5-1-5
P0300 The number of detected misfires is above the specified limit - An error detected by the misfire monitoring function in several cylinders - Check the condition of the plugs and cable connecting the engine cylinder injectors.
2-2-8
P0856 Physical implausibility of the request of the Torque Control System unit - Error in the operation of the Torque Control System unit - Check the condition and connection of the Torque Control System unit. Check the connection of the CAN line to other CAN devices.
3-4-3
P2530 The button is stuck or constantly pressed - Malfunction in the backup engine control start button circuit - Check the condition and connection of the backup engine control start button.
1-1-4
P0008 Backup mode is active - Start and operation of the engine is carried out only by the camshaft speed sensor - Check the condition and connection of the crankshaft speed sensor.
2-2-6
P0219 The maximum permissible crankshaft speed has been exceeded - The maximum permissible crankshaft speed has been exceeded - If the excess is due to incorrect gear shifting from high to low: if the engine is in order, you can continue driving. If the engine spontaneously increases speed, do not start the engine! Contact the service center immediately!
1-2-5
P1007 Implausible field appearance - The FMTC_trq2qBas_MAP field contains not strictly monotonic curves of the dependence of cyclic fuel supply on torque at fixed engine speeds - Contact the service center.
2-1-6
- P1008 Short circuit to battery - Malfunction in the fuel filter heating element circuit - Check the condition and connection of the fuel filter heating element.
- P1009 Short circuit to ground
2-1-1
P2269 The sensor detects the concentration of water in the fuel is higher than permissible - The concentration of water in the fuel recorded by the sensor is higher than permissible - Replace the fuel.
4-1-5
U0113 Timeout for EngGsFlowRt CAN message - EngGsFlowRt CAN message error - Check the connection of the CAN line to other CAN devices.
4-1-6
U1101 Timeout for HRVD CAN message - HRVD CAN message error - Check the connection of the CAN line to other CAN devices.
4-4-4
U0156 Timeout for RxAMCON CAN message - RxAMCON CAN message error - Check the connection of the CAN line to other CAN devices.
4-5-1
U1102 Timeout for RxEngTemp2 CAN message - RxEngTemp2 CAN message error - Check the connection of the CAN line to other CAN devices.
4-5-2
U1103 Timeout for TF CAN message - TF CAN message error - Check the connection of the CAN line to other CAN devices.
4-1-7
U1114 Timeout for TimeDate CAN message - Error and TimeDate CAN messages - Check the connection of the CAN line to other CAN devices.
2-6-5
- P062F Error during last read operation - Electrically erasable programmable read only memory (EEPROM) malfunction - Contact service.
- P062F Error during last write operation
- P062F Default value is used
2-6-1
P0607 The electronic unit has restarted - The electronic unit has restarted for hidden reasons - Contact the service center.
1-5-5
- P1300 The number of injections is limited by the load balance of the boost coordinator - Limitation of the number of fuel injections - You can continue driving. Contact the service center
- P1301 The number of injections is limited by the quantitative balance of the high pressure fuel pump
- P1302 The number of injections is limited by software settings
3-4-1
P0564 Inoperative switch combination - Malfunction in the cruise control actuator circuit - Check the condition and connection of the cruise control unit.
3-3-3
- P0650 Short circuit to battery - Malfunction in the power stage circuit for controlling the malfunction indicator lamp - Check the condition and connection of the malfunction indicator lamp.
- P0650 Short circuit to ground
- P0650 No load resistance
- P0650 Heating temperature exceeded
3-3-1
- P1619 Short circuit to battery - Malfunction in the power stage circuit for controlling the system diagnostic lamp - Check the condition and connection of the system diagnostic lamp.
- P161A Short circuit to ground
- P161B No load resistor
- P161C Heating temperature exceeded
3-3-4
- P162F Short circuit to battery - Malfunction in the power stage circuit for controlling the warning lamp - Check the condition and connection of the warning lamp.
- P1630 Short circuit to ground
- P1631 No load resistance
- P1632 Heating temperature exceeded
3-1-3
- P0647 Short circuit to battery - Malfunction in the power stage circuit of the air conditioner control - Check the condition and connection of the air conditioner.
- P0646 Short circuit to ground
- P0645 No load resistance
- P0645 Heating temperature exceeded
3-4-4
- P1000 Signal voltage above the specified maximum limit - Malfunction of the analog-to-digital converter channel for controlling the charge compressor regulator - Check the condition and connection of the charge compressor regulator
- P1001 Signal voltage below the specified minimum limit
- P1002 Defective signal
5-2-2
P160C The rail pressure monitoring functions are deactivated during the test - Error signal indicating that the high pressure circuit check test is being carried out
2-3-5
- P0073 Voltage above the maximum physical limit - Malfunction in the ambient air temperature sensor circuit, check the physical limit - Check the condition and connection of the ambient air temperature sensor.
- P0072 Voltage below the minimum physical limit
4-6-1
(U0434) The SPN received in the CAN message matches the SPN located in SPN block 1 - Error DM1DCU CAN message, SPN block 1 - Contact the service center.
4-6-2
(U0435) The SPN received in the CAN message matches the SPN located in SPN block 2 Error DM1DCU CAN message, SPN block 2 - Contact the service center.
4-6-3
(U0436) The SPN received in the CAN message matches the SPN located in SPN block 3 Error DM1DCU CAN message, SPN block 3 - Contact the service center.
4-6-4 (U0437) The SPN received in the CAN message matches the SPN located in SPN block 4 Error DM1DCU CAN message, SPN block 4 - Contact the service center.
4-6-5 (U0438) The SPN received in the CAN message matches the SPN located in SPN block 5 Error DM1DCU CAN message, SPN block 5 - Contact the service center.
4-6-6 (U0439) DM1DCU CAN message timeout DM1DCU CAN message error - Contact service center.