If the starter does not work when the ignition key is turned to position “II”, there may be a malfunction of both the starter itself and its activation circuit

To check, turn off the ignition and disconnect the wire block from the terminal of the starter traction relay windings.

Using a screwdriver, we bridge the terminal of the traction relay windings and the tip of the wire connected to the positive terminal of the battery

Checking the activation of the Lada Granta starter

Care must be taken when carrying out this operation, as sparking may occur in the area where the terminals are closed.

Do not connect the screwdriver to ground while closing the terminals!

If the crankshaft rotates, then the starter is working, and the cause of the malfunction is a violation in its activation circuit.

Otherwise, the starter or its traction relay is faulty.

If it is not possible to eliminate the malfunction in the activation circuit of a working starter, then, if necessary, in this way (by turning on the ignition and closing the terminals), you can start the engine and drive to the repair site.

Mounting fuse and relay block: 1 - relay for switching on the electric fan of the engine cooling system K1; 2 - relay for turning on the main beam headlights K7; 3 - relay for turning on the sound signal K8; 4 - door power window relay K2; 5 - starter relay K3; 6 - headlight high beam relay K1; 7 - additional relay K15/1; 8 - rear window heating relay K10; 9 - relay for turning on direction indicators and hazard warning lights K6; 10 - main relay of the engine control system K11; 11 - windshield wiper relay K6; 12 - relay for turning on the fuel pump K12; 13 - tweezers for removing fuses; 14 - tweezers for removing the relay; 15 - spare fuses F27-F30; 16 - working fuses F1- F26

A malfunction in the starter switching circuit can be caused by damage to: the starter relay, the power circuit or the control circuit of the ignition switch contact group relay, to find a fault in the starter switching circuit.

Checking the activation of the Lada Granta starter

Remove the starter relay from the mounting block.

To check the starter relay, install a known-good relay type 902.3747-11 in its place. To do this, you can use the adjacent power window relay.

If the starter turns on with the newly installed relay, then the starter relay has failed and must be replaced.

Otherwise, you need to check the power circuit and the starter relay control circuit.

To check the power circuit, remove the starter relay from the mounting block.

Checking the activation of the Lada Granta starter

Insert a jumper (piece of wire) into the sockets of the power contacts of the relay “30” and “87”.

Turn the ignition key to position “II” - “starter”.

If the starter turns on, the power circuit is working, if not, then use the tester

Checking the activation of the Lada Granta starter

Check whether “+12 V” is supplied to socket “30” of the starter relay when the ignition key is in position “II”.

In this case, the second (“negative”) tester probe can be connected to the door opening limiter mounting bolt.

If voltage is supplied to socket “30”, use a tester to check the integrity of the circuit from socket “87” of the starter relay to the tip of the starter traction relay control wire.

If voltage is not supplied to socket “30”, check the circuit from terminal “50” of the ignition switch to socket “30” of the relay.

If the circuit is in good condition, it is necessary to replace the ignition switch contact group.

If the starter power circuit is working properly, we check the starter relay control circuit - to do this, insert the tester probe into socket “86” of the starter relay, connect the second tester probe to ground.

Checking the activation of the Lada Granta starter

With the ignition on, check whether “+12 V” is being supplied from the main relay of the engine management system to socket “86” of the starter relay.

Checking the activation of the Lada Granta starter

Then we insert the tester probes into sockets “86” and “85” and check whether there is “ground” in socket “85” of the relay connected to pin “50” of the controller

Otherwise, we check the integrity of the starter relay control circuits from the main relay of the control system and output “50” of the controller - respectively to sockets “86” and “85” of the starter relay.